<entry>
<title>Evaluación de integridad y desarrollo de un plan de respuesta para un tramo de oleoducto</title>
<link href="https://rdi.uncoma.edu.ar/handle/uncomaid/19410" rel="alternate"/>
<author>
<name/>
</author>
<id>https://rdi.uncoma.edu.ar/handle/uncomaid/19410</id>
<updated>2026-05-27T18:18:01Z</updated>
<summary type="text">Evaluación de integridad y desarrollo de un plan de respuesta para un tramo de oleoducto
El presente trabajo evalúa la integridad del tramo de oleoducto NQN GR, construido en 1961 con tubería de costura longitudinal LF ERW, ante el aumento de la capacidad de transporte asociado al desarrollo de Vaca Muerta. La metodología integra datos de inspección interna inteligente, verificaciones en campo mediante ensayos no destructivos, análisis del sistema de protección anticorrosiva y gestión basada en riesgo. Además, se aplican modelos de resistencia remanente y de predicción del crecimiento de defectos por corrosión y por fatiga para analizar la aptitud para el servicio bajo las condiciones actuales y ante un incremento de presión. Los resultados muestran corrosión interna en el bajo topográfico del tramo, deterioro del revestimiento exterior, protección catódica insuficiente en sectores críticos y fisuración en la costura longitudinal. También se identifican áreas sensibles con franja de seguridad invadida, lo que incrementa las consecuencias de una pérdida de contención. Se concluye que los márgenes actuales son aceptables, pero el aumento de la presión reduce la vida remanente de los defectos planares y exige intervenciones previas y un plan de respuesta priorizado por riesgo.; This work evaluates the integrity of the NQN GR oil pipeline segment, built in 1961&#13;
with LF ERW longitudinal seam pipe, in view of the increase in transport capacity as-&#13;
sociated with the development of Vaca Muerta. The methodology integrates data from&#13;
intelligent inline inspection, field verification through nondestructive testing, analysis of&#13;
the anticorrosion protection system, and risk-based management. In addition, remaining-&#13;
strength and defect-growth prediction models for corrosion and fatigue are applied to&#13;
assess fitness-for-service under current conditions and with a pressure increase. The re-&#13;
sults show internal corrosion at the topographic low point of the segment, deterioration of&#13;
the external coating, insufficient cathodic protection in critical sectors, and cracking in the&#13;
longitudinal seam. Sensitive areas with encroached safety right-of-way are also identified,&#13;
increasing the consequences of a loss of containment. It is concluded that the current sa-&#13;
fety margins are acceptable, but the pressure increase reduces the remaining life of planar&#13;
defects and requires prior interventions and a risk-prioritized response plan.
</summary>
</entry>
<entry>
<title>Bioadsorbente magnético obtenido a partir de residuos de la producción de aceite de oliva para la remoción de metales pesados</title>
<link href="https://rdi.uncoma.edu.ar/handle/uncomaid/19402" rel="alternate"/>
<author>
<name/>
</author>
<id>https://rdi.uncoma.edu.ar/handle/uncomaid/19402</id>
<updated>2026-05-26T12:54:07Z</updated>
<summary type="text">Bioadsorbente magnético obtenido a partir de residuos de la producción de aceite de oliva para la remoción de metales pesados
La presencia de metales pesados (MP) en suelos, aguas superficiales y subterráneas como consecuencia de distintas actividades antropogénicas, tales como la minería, las operaciones metalúrgicas y la industria petroquímica, representa una importante problemática ambiental debido a su alta toxicidad, movilidad, persistencia y capacidad de bioacumulación. La incorporación de estos compuestos en sistemas acuosos puede ocasionar efectos contraproducentes en los ecosistemas, la vida acuática y los seres humanos.&#13;
Entre las distintas alternativas propuestas, el uso de bioadsorbentes (BA) derivados de residuos agroindustriales ha adquirido gran interés en los últimos años debido al bajo costo, disponibilidad y elevada presencia de grupos funcionales capaces de interactuar con especies metálicas. Asimismo, la incorporación de partículas magnéticas permite su recuperación mediante separación magnética.&#13;
En el presente trabajo se sintetizó un BA, funcionalizando partículas de magnetita con compuestos polifenólicos (Fe3O4-PF) extraídos de orujo de oliva proveniente de la industria olivícola regional de la provincia de Neuquén. Este extracto se obtuvo mediante extracción sólido-líquido con etanol y ácido cítrico.&#13;
Los materiales obtenidos fueron caracterizados mediante diversas técnicas fisicoquímicas, incluyendo difracción de rayos X (XRD, X-ray diffraction), microscopía electrónica de transmisión (TEM, transmission electron microscopy), espectroscopía infrarroja por transformada de Fourier (FTIR, Fourier transform infrared spectroscopy), análisis termogravimétrico (TGA, thermogravimetric analysis), y mediciones de potencial zeta (ζ), con el objetivo de evaluar su composición superficial, estructura cristalina, tamaño y estabilidad térmica. Los resultados obtenidos confirmaron la formación de magnetita/maghemita con estructura cristalina característica de tamaño nanométrico y evidenciaron la presencia de compuestos orgánicos asociados al recubrimiento con polifenoles.&#13;
Se evaluó la capacidad de adsorción de Fe3O4-PF y Fe3O4 ante diversos contaminantes. Para esto se realizaron ensayos de adsorción en modo batch utilizando soluciones acuosas de diferentes MP (Zn²⁺, Cd²⁺, Ni²⁺, Pb²⁺ y Cu²⁺). Considerando su toxicidad y lixiviación en condiciones ácidas, se utilizó Pb²⁺ como MP modelo. Las isotermas de adsorción se ajustaron mediante los modelos de Freundlich, Sips, BET y Dubinin–Radushkevich. Asimismo, considerando la naturaleza del material sintetizado se estudió la capacidad de adsorción con el colorante orgánico azul de metileno (AM).&#13;
Si bien el BA no presentó una mejora sustancial de la capacidad de remoción de Pb2+ como modelo de MP, sí se evidenció un gran incremento en la capacidad de adsorción de AM, lo que pone de manifestó la versatilidad que confiere el recubrimiento con sustancias polifenólicas.&#13;
&#13;
The presence of heavy metals (MP) in soils, surface waters, and groundwater as a result of anthropogenic activities such as mining, metallurgical operations, and the petrochemical industry represents a major environmental concern due to their high toxicity, mobility, persistence, and bioaccumulation capacity. The introduction of these compounds into aqueous systems may lead to adverse effects on ecosystems, aquatic life, and human health.&#13;
Among the different proposed alternatives, the use of bioadsorbents (BA) derived from agro-industrial residues has gained increasing attention in recent years due to their low cost, availability, and high density of functional groups capable of interacting with metal species. Furthermore, the incorporation of magnetic particles enables their recovery by magnetic separation.&#13;
In this work, a BA was synthesized by functionalizing magnetite particles with polyphenolic compounds (Fe3O4-PF) extracted from olive pomace from the regional olive industry in Neuquén Province. The extract was obtained by solid–liquid extraction using ethanol and citric acid.&#13;
The obtained materials were characterized using various physicochemical techniques, including X-ray diffraction (XRD), transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and zeta potential (ζ) measurements, in order to evaluate their surface composition, crystalline structure, size, and thermal stability. The results confirmed the formation of magnetite/maghemite with a characteristic crystalline structure at the nanoscale and evidenced the presence of organic compounds associated with the polyphenolic coating.&#13;
The adsorption capacity of Fe3O4-PF and Fe3O4 was evaluated against different contaminants. Batch adsorption experiments were carried out using aqueous solutions containing different MP (Zn²⁺, Cd²⁺, Ni²⁺, Pb²⁺ and Cu²⁺). Considering its toxicity and lixiviation under acidic conditions, Pb²⁺ was selected as the model MP. Adsorption isotherms were fitted using Freundlich, Sips, BET and Dubinin–Radushkevich models. Additionally, considering the nature of the synthesized material, its adsorption capacity toward the organic dye methylene blue (AM) was also studied.&#13;
Although the BA did not show a significant improvement in Pb²⁺ removal as a model MP, a substantial increase in AM adsorption capacity was observed, highlighting the versatility provided by the polyphenolic coating.; The presence of heavy metals (MP) in soils, surface waters, and groundwater as a result of&#13;
anthropogenic activities such as mining, metallurgical operations, and the petrochemical&#13;
industry represents a major environmental concern due to their high toxicity, mobility,&#13;
persistence, and bioaccumulation capacity. The introduction of these compounds into aqueous&#13;
systems may lead to adverse effects on ecosystems, aquatic life, and human health.&#13;
Among the different proposed alternatives, the use of bioadsorbents (BA) derived from agro-&#13;
industrial residues has gained increasing attention in recent years due to their low cost,&#13;
availability, and high density of functional groups capable of interacting with metal species.&#13;
Furthermore, the incorporation of magnetic particles enables their recovery by magnetic&#13;
separation.&#13;
In this work, a BA was synthesized by functionalizing magnetite particles with polyphenolic&#13;
compounds (Fe3O4-PF) extracted from olive pomace from the regional olive industry in Neuquén&#13;
Province. The extract was obtained by solid–liquid extraction using ethanol and citric acid.&#13;
The obtained materials were characterized using various physicochemical techniques, including&#13;
X-ray diffraction (XRD), transmission electron microscopy (TEM), Fourier-transform infrared&#13;
spectroscopy (FTIR), thermogravimetric analysis (TGA), and zeta potential (ζ) measurements, in&#13;
order to evaluate their surface composition, crystalline structure, size, and thermal stability. The&#13;
results confirmed the formation of magnetite/maghemite with a characteristic crystalline&#13;
structure at the nanoscale and evidenced the presence of organic compounds associated with&#13;
the polyphenolic coating.&#13;
The adsorption capacity of Fe3O4-PF and Fe3O4 was evaluated against different contaminants.&#13;
Batch adsorption experiments were carried out using aqueous solutions containing different MP&#13;
(Zn²&#13;
⁺, Cd²&#13;
⁺, Ni²&#13;
⁺, Pb²&#13;
⁺ and Cu²&#13;
⁺). Considering its toxicity and lixiviation under acidic conditions,&#13;
Pb²&#13;
⁺ was selected as the model MP. Adsorption isotherms were fitted using Freundlich, Sips, BET&#13;
and Dubinin–Radushkevich models. Additionally, considering the nature of the synthesized&#13;
material, its adsorption capacity toward the organic dye methylene blue (AM) was also studied.&#13;
Although the BA did not show a significant improvement in Pb²&#13;
⁺ removal as a model MP, a&#13;
substantial increase in AM adsorption capacity was observed, highlighting the versatility provided&#13;
by the polyphenolic coating.
</summary>
</entry>
<entry>
<title>Análisis y simulación del régimen permanente y de los transitorios hidráulicos del sistema de bombeo de agua para el abastecimiento de un yacimiento hidrocarburífero</title>
<link href="https://rdi.uncoma.edu.ar/handle/uncomaid/19319" rel="alternate"/>
<author>
<name/>
</author>
<id>https://rdi.uncoma.edu.ar/handle/uncomaid/19319</id>
<updated>2026-05-07T11:26:26Z</updated>
<summary type="text">Análisis y simulación del régimen permanente y de los transitorios hidráulicos del sistema de bombeo de agua para el abastecimiento de un yacimiento hidrocarburífero
El presente proyecto busca analizar el comportamiento hidráulico de un sistema de bombeo de agua en régimen permanente y transitorio, poniendo especial énfasis en los efectos del golpe de ariete. El sistema estudiado está compuesto por una estación de bombeo que impulsa el caudal a través de un acueducto de acero de gran longitud y perfil topográfico variable, descargando a un sistema de almacenamiento a presión atmosférica. Mediante simulaciones numéricas realizadas con el software Allievi, se evalúan las presiones y velocidades máximas y mínimas generadas durante el escenario más desfavorable, correspondiente al paro repentino de las bombas. Con el objetivo de mitigar estos efectos, se analizan distintas alternativas de protección frente a transitorios hidráulicos, considerando su desempeño hidráulico, viabilidad técnica y aspectos económicos. A partir del análisis comparativo, se selecciona como solución final la combinación de un calderín ubicado a la salida de la estación de bombeo y dos ventosas instaladas en puntos estratégicos del acueducto, logrando una adecuación en las magnitudes máximas y mínimas de presiones y garantizando un funcionamiento seguro y confiable del sistema.; The present project aims to analyze the hydraulic behavior of a water pumping system under steady-&#13;
state and transient conditions, with special emphasis on the effects of water hammer. The system under&#13;
study consists of a pumping station that conveys flow through a long steel aqueduct with a variable&#13;
topographic profile, discharging into an atmospheric storage system. Through numerical simulations&#13;
performed using Allievi software, the maximum and minimum pressures and velocities generated&#13;
during the most unfavorable scenario—corresponding to the sudden shutdown of the pumps—are&#13;
evaluated. In order to mitigate these effects, different protection alternatives against hydraulic&#13;
transients are analyzed, considering their hydraulic performance, technical feasibility, and economic&#13;
aspects. Based on the comparative analysis, the final solution selected consists of the combination of&#13;
a surge tank installed at the outlet of the pumping station and two air valves located at strategic points&#13;
along the aqueduct, achieving adequate control of maximum and minimum pressure magnitudes and&#13;
ensuring safe and reliable system operation.
</summary>
</entry>
<entry>
<title>Estudio de prospección geoeléctrica para la caracterización litológica del subsuelo en futura construcción de torres, Neuquén Capital - Provincia del Neuquén</title>
<link href="https://rdi.uncoma.edu.ar/handle/uncomaid/19317" rel="alternate"/>
<author>
<name/>
</author>
<id>https://rdi.uncoma.edu.ar/handle/uncomaid/19317</id>
<updated>2026-05-07T11:25:18Z</updated>
<summary type="text">Estudio de prospección geoeléctrica para la caracterización litológica del subsuelo en futura construcción de torres, Neuquén Capital - Provincia del Neuquén
El presente estudio se enfoca en implementar el método de prospección geoeléctrica, específicamente &#13;
el de las tomografías de resistividad eléctrica (ERT) como una herramienta complementaria que brinda &#13;
ayuda y aporta información significativa a la hora de caracterizar la litología del subsuelo para estudios &#13;
geotécnicos. Esta herramienta poco utilizada en el campo de la geotecnia, mide la propiedad de la &#13;
resistividad eléctrica de los materiales del subsuelo frente al paso de la corriente eléctrica, permitiendo &#13;
identificar la distribución espacial de la resistividad e inferir características litológicas que determinen &#13;
las condiciones adecuadas de cimentación. &#13;
La investigación se lleva a cabo en un predio ubicado en la ciudad de Neuquén, donde se realiza un &#13;
estudio preliminar de suelos para la fundación de edificios de gran envergadura. En este contexto, se &#13;
implementa la prospección geoeléctrica como parte del análisis del subsuelo. &#13;
El estudio consistió en la interpretación de los datos obtenidos a partir de seis (6) tomografías de &#13;
resistividad eléctrica, el procesado de las mismas se realizó mediante la inversión de los datos utilizando &#13;
el software ZondRes2D, con este procedimiento se obtuvieron valores de resistividad real del subsuelo &#13;
permitiendo inferir litologías, la distribución espacial de la misma y generar un modelado bidimensional &#13;
(2D) del sitio prospectado. &#13;
Luego, en base a los resultados obtenidos y una  comprensión adecuada de la geología local, se &#13;
procede a integrar y correlacionar los resultados con dos perforaciones realizadas en el área de estudio. &#13;
Se demuestra que la integración adecuada de las tomografías de resistividad eléctrica combinadas con &#13;
los métodos convencionales directos permite una interpretación más eficiente y precisa del subsuelo al &#13;
mejorar la cobertura analizada en la investigación. Como resultado se obtiene una mayor cantidad de &#13;
información proporcionando mejor calidad de la misma, lo que resulta en una evaluación litológica más &#13;
detallada desde el punto de vista geotécnico, al obtener perfiles geológicos detallados del subsuelo a &#13;
fundar.; This study focuses on implementing the geoelectric prospecting method, specifically electrical&#13;
resistivity tomography (ERT), as a complementary tool that helps and provides significant information&#13;
when evaluating subsoil lithology for geotechnical studies. This tool, which is rarely used in the field of&#13;
geotechnics, measures the electrical resistivity of subsoil materials when an electric current passes&#13;
through them, allowing lithological characteristics to be inferred.&#13;
The research is being conducted on a site located in the city of Neuquén Capital, where a preliminary&#13;
soil study is being carried out for the foundation of large-scale buildings. In this context, geoelectric&#13;
prospecting was implemented as part of the subsoil analysis.&#13;
The study consisted of interpreting data obtained from six (6) electrical resistivity surveys, processing&#13;
them using data inversion with ZondRes2D software, and obtaining actual subsurface resistivity values&#13;
through this procedure, allowing lithologies to be inferred and a two-dimensional (2D) model of the&#13;
surveyed site to be generated.&#13;
Then, based on the resistivity results obtained from the tomography and an adequate knowledge of&#13;
the local geology, the results were integrated and correlated with two boreholes drilled in the study area.&#13;
It has been verified that the integration of electrical resistivity tomography with conventional direct&#13;
methods allows for a more efficient and accurate interpretation of the subsoil by improving the spatial&#13;
coverage of the investigation. As a result, a greater amount of information is obtained, providing better&#13;
quality data, which results in a more detailed lithological evaluation from a geotechnical point of view,&#13;
by obtaining detailed geological profiles of the subsoil to be founded
</summary>
</entry>